Reznor ADFH Operation Manual Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Heizkörper Reznor ADFH Operation Manual herunter. Reznor ADFH Operation Manual User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Form O-ADF/RDF, P/N 148385R2, Page 1
KEEP THIS BOOKLET FOR
MAINTENANCE AND SERVICE REFERENCE.
Applies to: Indoor or Outdoor, Gas, Direct-Fired,
Makeup Air/Heating Systems
Model RDF and Models ADF/ADFH
Form O-ADF/RDF (Version A)
Obsoletes Form O-DV/RDF/ADF
Operation / Maintenance / Service
Model ADF
Model RDF
!
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or
property damage.
Be sure to read and understand the installation, operation, and service instructions in
this manual.
Improper installation, adjustment, alteration, service, or maintenance can cause
serious injury, death, or property damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a phone remote from the building. Follow
the gas suppliers instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency,
or the gas supplier.
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - WARNING:

Form O-ADF/RDF, P/N 148385R2, Page 1KEEP THIS BOOKLET FOR MAINTENANCE AND SERVICE REFERENCE.Applies to: Indoor or Outdoor, Gas, Direct-Fired, Makeup

Seite 2 - Table of Contents

Form O-ADF/RDF, P/N 148385R2, Page 103.0 Operation and Service (cont'd)• High Airow SwitchFunction: The high airow switch is a velocity pressur

Seite 3 - 2.0 Maintenance

Form O-ADF/RDF, P/N 148385R2, Page 11If the pilot ame rod does not sense a pilot ame, the controller shuts down the pilot valve for a 10-second inte

Seite 4

Form O-ADF/RDF, P/N 148385R2, Page 123.0 Operation and Service (cont'd)The electronic modulating-type gas controls act in response to discharge a

Seite 5

Form O-ADF/RDF, P/N 148385R2, Page 13• Electronic Modulation Makeup Air Gas Control Option AG37Amplier, P/N 133229Selector, P/N 133230FIGURE 23 - C

Seite 6

Form O-ADF/RDF, P/N 148385R2, Page 143.0 Operation and Service (cont'd)3.6 Gas Train Including Burner, Gas Controls, Manifold Arrangements, and G

Seite 7 - Maintenance

Form O-ADF/RDF, P/N 148385R2, Page 15FIGURE 29 - Gas Pressure SwitchesLow Gas Pressure Switch, P/N 204375(automatic)High Gas Pressure Switch, P/N 204

Seite 8 - 3.0 Operation and

Form O-ADF/RDF, P/N 148385R2, Page 163.0 Operation and Service (cont'd)Function: The potentiometer is a manually set switch that operates eithe

Seite 9 - Switches

Form O-ADF/RDF, P/N 148385R2, Page 17FIGURE 35 - Door Switch, P/N 124253Door Switch (Option BX1)Location: The control is installed on an overhead door

Seite 10 - (cont'd)

Form O-ADF/RDF, P/N 148385R2, Page 183.0 Operation and Service (cont'd)3.9 TroubleshootingChart 1 - System Troubleshooting (Check the diagnostic

Seite 11

Form O-ADF/RDF, P/N 148385R2, Page 1915. Disconnect closed; blower and burner switches in run position; control switch is in "winter" positi

Seite 12

Form O-ADF/RDF, P/N 148385R2, Page 21.0 GeneralThe information in this manual applies to Model Series RDF and ADF direct-red heat-ing/makeup air syst

Seite 13

Form O-ADF/RDF, P/N 148385R2, Page 20www.ReznorHVAC.com(800) 695-1901©2014 Reznor, LLC. All rights reserved.Trademark Note: Reznor® is registered in a

Seite 14

Form O-ADF/RDF, P/N 148385R2, Page 32.0 Maintenance 2.1 Maintenance RequirementsThis direct-red makeup air system is designed to require only a minim

Seite 15 - Controls

Form O-ADF/RDF, P/N 148385R2, Page 4The blower, motor and drive components are located in the blower cabinet. Remove the panels required to access the

Seite 16

Form O-ADF/RDF, P/N 148385R2, Page 5S 2.3.4 Air PressureProle plate sensing tubes should be checked quarterly and cleaned no less than se

Seite 17

Form O-ADF/RDF, P/N 148385R2, Page 62.3.7 Optional Evaporative Cooling ModuleMedia - Over time, excessive amounts of mineral deposits will begin to bu

Seite 18 - 3.9 Troubleshooting

Form O-ADF/RDF, P/N 148385R2, Page 7FIGURE 6 - Re

Seite 19 - References

Form O-ADF/RDF, P/N 148385R2, Page 82.0 Maintenance (cont'd)2.3 Maintenance Procedures (cont'd)2.3.7 Optional Evaporative Cooling Module (co

Seite 20 - (800) 695-1901

Form O-ADF/RDF, P/N 148385R2, Page 9Column of 13 indicator bulbs; always replace burned out bulbs, P/N 125189.