Reznor LDAP Unit Installation Manual Bedienungsanleitung Seite 43

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 42
Form I-LDAP, P/N 207733R6, Page 43
Index
A
Abnormal Heat Cycle
Functions 30
B
Burner Removal 35
Burner Service 35
C
Check installation after
Startup 33
Check Installation and Start-
Up 32
Clearances 7
Combustion Air 4
Combustion Air Pressure
Switch 40
Combustion Air Proving
Switch 27
Conned Space 4
Contact 44
D
Destratication 28
Pipe Diameter 17
Discharge Louvers, Option
CD32 15
Discharge Nozzle Options
15
E
Electrical Supply and
Connections 20
F
Continuous Fan Operation
31
Fan 39
Fan Blades 39
Fan Control 28, 40
Fan Motor 39
Fault Modes 31
Flame Rollout Switch 28, 40
Flame Sensor 38
G
Gas Piping and Pressures
10
Gas Valve 23, 39
H
HAZARD INTENSITY
LEVELS 2
Heater Startup and Warnings
32
Heat Exchanger Service 35
High Altitude Derate 13
High Altitude Operation 6
High Limit Control 28, 40
Horizontal Vent Terminals 19
I
Ignition System 28, 37
Ignitor 37
Installation Codes 3
INSTALLATION RECORD
44
L
Vent Length 17
LED signal lights 41
Limit Control 27, 40
Location of Controls 35
Lockouts 31
Louver Installation 15
Louvers 15
M
Maintenance 34
Maintenance Schedule 34
O
Operating Instructions 32
Operating Sequence 29
S
Service 34
Compression Springs 15
Startup 32
Suspending 8
T
Terminal (Pipe and Vent Cap)
19
Transformer 40
DSI Integrated Control
Module (Circuit Board) Trial
Troubleshooting Flowchart
41
General Troubleshooting 42
Troubleshooting 41
U
Uncrating and Preparation 6
V
Main Venter Motor 38
Venter (Flue) Outlet 17
Venter Motor 38
Venting 16
Venting Requirements 16
Vent Pipe 16
Vent System 40
Vent System Testing 33
W
Wall Mounting 9
Warranty 3
Weight 8
Wiring Diagrams 23
APPENDIX
Technical Data
Model LDAP Size 400 800 1200
Input Heating Capacity
btuh 400,000 800,000 1,200,000
kw/h 117.1 234.2 351.4
Thermal Efciency (%) 83 83 83
Output Heating Capacity
btuh 332,000 664,000 996,000
kw/h 97.2 194.4 291.6
Gas Connection (Inches) 1 1-1/4 1-1/4
Vent Connection Diameter (Inches) 6 8 8
Control Amps (24 volt) 1.0 2.0 3.0
Full Load Amps (208 volt) 5.6 13.6 19.4
Full Load Amps (230 volt) 5.5 12.8 18.5
Normal Power Consumption @ 208V (watts) 1150 2448 3730
Normal Power Consumption @ 230V (watts) 1230 2597 3959
Discharge Air Temperature Rise (°F) 55 55 55
Air Volume (Heat @ High Speed)
cfm 5589 11178 16768
m
3
/minute 158 317 475
Discharge Air Opening Area
ft
2
3.67 7.35 11.02
m
2
0.34 0.68 1.02
Outlet Velocity (Heat @ High
Speed)
fpm 1521 1521 1521
m/minute 464 464 464
Air Volume (Destratication @
Medium Speed)
cfm 4650 9300 13950
m
3
/minute 132 263 395
Outlet Velocity (Destratication @
Medium Speed)
fpm 1266 1266 1266
m/minute 386 386 386
Air Volume (Destratication @
Low Speed)
cfm 3250 6500 9750
m
3
/minute 92 184 276
Outlet Velocity (Destratication @
Low Speed)
fpm 885 885 885
m/minute 270 270 270
Fan Motor HP (Qty) 1 (1) 1 (2) 1 (3)
Fan Motor RPM 1050 1050 1050
Fan Diameter (Inches) 24 24 24
Model LDAP 400
Model LDAP 800
Model LDAP 1200
One
Downow
Heater
One Heater
with Two
Downow
Heat Sections
One Heater with Three
Downow Heat Sections